STT Transverse Thruster

Technical Data

FP -Type

Pmax*

Aux

[kW]

Pmax**

DP

[kW]

Input

Speed***
[rpm]

Propeller ø
[m]
Tunnel length
[m]

Approx.

Weight***
[t]

Standard operation with FP propeller and electric prime mover *
STT 60 T100-12585-1051200 / 15000,451,000,49
STT 60100-125

85-105

1200 / 15000,621.000.56
STT 110160-200150-1801200 /15000,791.000.89
STT 170 T290-315230-3001200 / 1500 / 18000,991.501.68
STT 170280-350200-3151200/ 1500 / 18001.091.501.73
STT 1500-550380-5001200 / 1500 / 18001.241.503.00
STT 2690-850610-7601200 /1500 / 18001.541.504.50
STT 3815-1000745-9001200 / 1500 / 18001.742.006.40
STT 41300-14001000-12001000 / 12001.992.009.40
STT 51500-18001200-15001000 /12002.242.3510.50
STT 62000-22001800-2000900 / 10002.592.7517.00
STT 72400-28002200-2500900 /10002.792.8021.00
STT 83000-34002500-30007503.293.0132.00
CP -Type

Pmax*

Aux

[kW]

Pmax**

DP

[kW]

Input

Speed***
[rpm]

Propeller ø
[m]
Tunnel length
[m]

Approx.

Weight***
[t]

STT 1500-600430-4501200 / 1500 / 18001.291.703.50
STT 2690-850625-6501200 / 1500 / 18001.542.004.60
STT 3815-1000745-9001200 / 1500 / 18001.742.106.50
STT 41200-14001000-12001000 / 12001.992.309.50
STT 51500-18001200-15001000 / 12002.242.8012.10
STT 62100-24001900-2000900 /10002.593.2518.60
STT 72500-28002300-2500900 / 10002.793.4022.50

depending on

* prime mover type and input speed rpm

** prime mover type, input rpm, classification society

*** prime mover type and slip

**** final scope of supply and design

 

 

Specification is subject to change without notice.

Data are a guideline for projects.